![]() IEI 232e Standalone Installation/ Programming Manual 1. Button and Door Contacts Installing the Plug-On Relay Board Wiring the Standalone Access Control Relays Section 6: Testing the Keypad Section 7: Programming Programming Main Relay Time Programming Users Programming Keypad Options Section 8: Troubleshooting Section 9: Programming Mode Loopback Section 10: Warranty Manual Revision Date: 05/16/03 Firmware Version: Document # 6054004, Rev. Shunting a Normally Closed Zone Wiring Remote Trigger as Request to Exit (REX). Wiring the 232e Keypad to an Electric Strike (Fail-Secure). Programming Manual Contents Section 1: Features and Product Description Features Product Description Section 2: Requirements Section 3: Specifications Section 4: Mounting Section 5: Wiring Wire Harness Configuration Wiring the 232e Keypad to a Maglock (Fail-Safe). Phone: 80, 78 Fax: 78 Website: Document #: 6104402, Rev 2.Example: marketing Search IEI 232e Standalone Keypad Installation/ Programming … Then connect the two using 22 AWG stranded and shielded cable. If your Output Module is located more than 18 inches from the keypad (up to a maximum of 100 feet), you must cut the wire harness in half and plug one half into the keypad the other into the Output Module. Wiring the 2000-8EX Output Module If the Output Module is within 18 inches of the keypad, use the 6conductor wire harness, supplied with the Output Module, to make the connection. Programming Keypad Parameters (Default settings are in bold) Command/Action Change Keypad Parameters Keys to Enter/Details 32 # parameter # value # ** Parameter Value 0 – Duress Output Duration 1 – 255 Seconds (default = 5) 1 – Panic Output Duration* 1 – 255 Seconds (default = 5) 2 – Error Lockout Threshold 1 – 50 Attempts (default = 3) 3 – Error Lockout Duration 1 – 255 Seconds (default = 10) 4 – Auto-Entry Count 2 – 10 Digits (default = 4) 7 – Auto-Entry Keypress 2 – 15 Seconds (default = 2) Timeout 10 Using command 10, you can assign any Virtual Output to any Physical Output or disable a Physical Output.Physical Outputs include the main relay and aux relay on the keypad, the eight relays on the 20008EX Output Module and the two audio alerts on the keypad. Virtual Outputs are functions that you can assign to operate any Physical Output. Exit Program Mode Press: * (Yellow LED Stops Flashing) Programming a Supervisor Code Use the following command sequence to program a supervisor code, which is stored user location 2.Īssigning Virtual Outputs to Physical Outputs (Standalone Mode Only) The keypad is equipped with nineteen Virtual Outputs and twelve Physical Outputs. ![]() Change Master Code Press: 1 # new master code * repeat code * (Yellow LED Flashes Slowly) 3. Enter Program Mode Press: 99 # master code * (Yellow LED Flashes Slowly) 2. 2.Ĭhanging the Master Code The first step in setting up your keypad is to enter program mode and change the master code. Connect the red wire (V+) to the blue wire (common), and then connect them to the positive on the power supply. ![]() Wiring an Electric Door Strike (FailSecure) 1. Connect the black wire (V-) to the negative on the Maglock, and then connect them both to the negative on the power supply. Connect the gray wire (normally closed) to the positive on the Maglock. Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction. This section contains information regarding the requirements necessary to meet UL compliance. ![]() ![]() The 2000e/2000eM keypad is a UL Listed access control unit. Below is a brief explanation of each mode.Ĭircuit Board Diagram UL Requirements Note: J3 is for use only with the 2000-8EX Output Module. Keypad Operating Modes 2000 Series The 2000e/2000eM keypad has three operating modes: Standalone e/eM Style Keypad Mode, Secured Series Front End Mode and Wiegand Front End Installation and Programming Guide Mode. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |